Dahua Technology COP Security ITC237-PU1A-IRHL 빠른 설치 매뉴얼 - 페이지 5
{카테고리_이름} Dahua Technology COP Security ITC237-PU1A-IRHL에 대한 빠른 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dahua Technology COP Security ITC237-PU1A-IRHL 12 페이지.
CONFIGURATION
Once the camera has been mounted and all connections terminated, use a PC or Laptop connected to the same network switch
as the ANPR to login to the web browser interface. By default the IP address of the camera is 192.168.1.108, if required this can be
changed via the Config Tool or within the camera web browser.
Login to the camera via the computers web browser. Username:
NOTE: When connecting to an NVR it is vital to use the correct login credentials in the NVR remote device menu. Failure to input the
correct credentials will lock the camera until the correct credentials are used and the camera is rebooted.
Live View
Logged Plate
Number
Plate
Snapshot
Once logged into the camera the live display will be shown.
To configure the camera lens and recognition settings, first select the install button.
The camera has built in electric back focus, this allows for adjustments to the focus to be made via the web browser (manual focus
is still required initially). To use this feature select the AutoFocus button.
Select the Region button and then Redraw, use the left mouse button to draw the detection area that vehicles will pass through.
Tel: +44 (0)1457 874 999 | Fax: +44 (0)1457 829 201 | Email: [email protected] | Online: www.cop-eu.com
admin123
admin
Password:
Install
Full Screen
Snapshot
Event List