DPI Xcel 7QP-12F950P25-C00 매뉴얼 - 페이지 7

{카테고리_이름} DPI Xcel 7QP-12F950P25-C00에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DPI Xcel 7QP-12F950P25-C00 15 페이지. 10-channel/bank 6,8,12v battery charger

 The MODE Setting affects all Channels simultaneously. If, for example, the
factory preset MODE-1 is used, any and all batteries connected to the
outputs must be the same or very similar Lead Acid Batteries.
The CHARGE MODE VALUES AND SETTINGS is selected via the use of the
MENU button. Follow these steps to select an alternate Charge MODE:
Hold depressed the MENU Button for 3 seconds, then release. The LCD displays
the CHARGE MODE menu.
Depress/release the MENU Button again, which then displays the SOFTWARE
VERSION menu.
Depress/release the MENU Button again, which then displays the CHARGE
MODE SELECT Menu
Now, depress and hold depressed for 3seconds again, and then release the
MENU Button to enter into the CHARGE MODE operation.
o
o
o
CHARGE MODE VALUES AND SETTINGS TABLE
MODE
Battery Type/Name
01
12V General Lead Acid
02
12V General Lead Acid
03
12V General Lead Acid
04
12V General Lead Acid
05
12V General Lead Acid
06
12V General Lead Acid
07
12V General Lead Acid
08
12V General Lead Acid
09
6V General Lead Acid
10
6V General Lead Acid
11
6V General Lead Acid
12
6V General Lead Acid
13
6V General Lead Acid
14
6V General Lead Acid
15
6V General Lead Acid
16
6V General Lead Acid
17
12V GEL Lead Acid
18
12V GEL Lead Acid
19
6V General Lead Acid
20
6V General Lead Acid
21
6V General Lead Acid
22
12V Odyssey PC680
23
12V Optima OPT-D31M
24
8V General Lead Acid
25
4cell Lithium – 'Green'
26
4cell Lithium – 'Green'
27
3cell Lithium – 'ION'
28
3cell Lithium – 'Green'
29
2cell Lithium – 'ION'
30
2cell Lithium – 'Green'
31
1cell Lithium – 'ION'
32
1cell Lithium – 'Green'
Each depress/release of the MENU button now increments the MODE
Number
Stop depressing/releasing the MENU button when the desired MODE
Number is reached
Hold depressed for 3 seconds the MENU Select Button to select the
new MODE setting chosen, then release to select the CHARGE MODE
that is displayed. If this action is not performed, the function times out,
exits and returns without changing to a new CHARGE MODE.
Type
AH
Flooded
32AH
AGM
32AH
Flooded
18AH
AGM
18AH
Flooded
10AH
AGM
10AH
Flooded
5AH
AGM
5AH
Flooded
32AH
AGM
32AH
Flooded
18AH
AGM
18AH
Flooded
10AH
AGM
10AH
Flooded
5AH
AGM
5AH
Flooded
40AH
Flooded
90AH
Flooded
225AH
AGM
213AH
AGM
220AH
Pure Lead
16AH
Spiral
75AH
Flooded
170AH
LiFePO
30AH
LiFePO
15AH
Li+ Ion
20AH
LiFePO
15AH
Li+ Ion
20AH
LiFePO
15AH
Li+ Ion
5AH
LiFePO
5AH
7
Volts/Cell*
2.400V
2.450V
2.400V
2.450V
2.400V
2.450V
2.400V
2.450V
2.400V
2.450V
2.400V
2.450V
2.400V
2.450V
2.400V
2.450V
2.333V
2.333V
2.400V
2.400V
2.450V
2.433V
2.450V
2.400V
3.650V
3.650V
4.050V
3.650V
4.050V
3.650V
4.050V
3.650V