7. Disconnect the wire connectors along the left side of the
control board as numbered 1, 2, 3, 4 , 5 & 6 in
Figure 17: Disconnect the wire connectors along the left
side of the control board, numbered 1, 2, 3, 4, 5 & 6
#4- Indoor Fan Connector
8. Cut the Orange and Purple wires on the Indoor Fan
Connector (labeled #4 in
from the connector. Strip back 1/4" on each wire.
IM 871-3
Figure
Premium
Control Board
Figure
18), approximately 2" back
Figure 18: Cut two wires on the fan connector, (orange and
purple), 2 inches back from the board connector
17.
#4- Indoor Fan Connector
cut orange & purple wires
2" back from plug
9. Refer to
Figure 19
(detached from the plug connector) into the kit-provided
butt connector, and crimp. In the opposite end of the butt
connector insert the orange wire (attached to the plug
connector) and the orange wire from the kit-provided fan
motor wire harness, and crimp. Repeat for Purple wire
(using pink wire from the kit motor wire harness).
Figure 19: Make wire connections between the indoor fan
plug wires and the boost fan motor wire harness
Butt
Connectors
Attach ground wire
See
Figure 20
Premium
Control Board
and insert the end of the orange wire
White wire with
piggy-back connector
for L2 Standby
Page 9 of 12