Electrolux 95G 지침 책자 - 페이지 17

{카테고리_이름} Electrolux 95G에 대한 지침 책자을 온라인으로 검색하거나 PDF를 다운로드하세요. Electrolux 95G 20 페이지. Gas and mixed fuel cookers
Electrolux 95G에 대해서도 마찬가지입니다: 지침 책자 (20 페이지), 사용 설명서 (24 페이지), 지침 책자 (20 페이지)

Electrolux 95G 지침 책자
Replacement of oven burner nozzle
To replace the oven nozzle, follow this procedure:
a)
remove the bottom of the oven;
b)
unscrew screw 1 (Fig. 25) and take the oven burner out;
c)
with a socket spanner 7 unscrew and remove the nozzle, situated
in the bottom of the oven, and replace it with the proper one (see
Technical data);
d)
reassemble the burner following the same procedure backwards.
Replacement of grill burner nozzle
To replace the grill burner nozzle, act as follows:
a) remove the screws, marked with letter "A" in Fig. 26;
b) take the grill burner out;
c) with a socket spanner n. 7, unscrew and remove the nozzle,
situated in the oven top, and replace it with the proper one (see
Technical data);
d) undo the fixing screw of the metal ring of primary air adjustment
and adjust the relevant opening (see diagram);
e) reassemble the burner following the same procedure backwards.
Minimum level adjustment of oven burner
After setting the oven on maximum temperature with closed door
for about 10 minutes, turn the knob of the thermostat on MIN.,
remove the knob and:
— in case of conversion from natural gas to liquid gas, tightly
screw the by-pass pin of thermostat;
— in case of conversion from liquid gas to natural gas, unscrew
about one-half turn by-pass pin, until a regular small flame is
reached.
— in case of conversion from liquid gas to town gas, unscrew
about one turn by-pass pin, until a regular small flame is reached.
— in case of conversion from natural gas to town gas, unscrew
about one turn by-pass pin, until a regular small flame is reached.
The oven burner does not need any primary air regulation.
Adjustment of thermostat by-pass pin
To reach the thermostat by-pass pin, act as follows:
-
take out the knobs;
-
remove the front panel;
-
adjust the by-pass pin with a thin screwdriver, as shown in Fig. 27;
-
finally check that turning quickly the tap from maximum position
to minimum position, the flame does not go out;
-
reassemble the front panel and the knobs.
WARNING
If the pressure of gas used is different (or variable) from that
foreseen, an appropriate pressure regulator must be installed on
the entry tube. in case of pressure regulators for GPL are used,
these must conform to regulation.
Replacement of the gas adjustement plate
After the gas adjustment operation of the new appliance to the
new type of gas has been completed, please replace the gas
adjustment plate (located next to the connection pipe) with the
gas adjustment plate that relates to the new type of gas being
used. The gas adjustment plate can be found in the envelope
containing the documents (e.g. the guarantee etc.).

Insertion possibility

In case of insertion of the appliance between kitchen units, the
dimensions to be respected are shown in Fig. 28.
When the kitchen is installed according to class 2, sub-class
1 (i.e. built-in) for the gas connection use only flexible metallic
tubes conforming to rules in force.
Fig. 26
Natural gas adjustment: full opening width
Liquid gas adjustment: opening 10 mm wide
Fig. 27
100
Fig. 28
A
1 7