Draper SLX17 설치 및 운영 지침 매뉴얼

{카테고리_이름} Draper SLX17에 대한 설치 및 운영 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Draper SLX17 7 페이지. 230v ac scissor lift slx video projector lift
Draper SLX17에 대해서도 마찬가지입니다: 브로셔 및 사양 (16 페이지), 설치 및 운영 매뉴얼 (7 페이지), 설치 및 운영 지침 매뉴얼 (7 페이지), 설치 및 작동 지침 (8 페이지)

Draper SLX17 설치 및 운영 지침 매뉴얼
230V AC Scissor Lift SLX Video Projector Lift by Draper
These Installation/Operating Instructions are available in the official language of the
country where you purchase the product. Please contact your distributor to request a copy.
Vous pourriez demander les instructions d'installation et d'opération traduises dans la
langue officielle du pays ou vous achetez le produit. Veuillez demander à votre distributeur.
Die Gebrauchsanweisung für Installation und Konstruktion sind in der offiziellen
Sprache des Landes, indem Sie das Produkt gekauft haben, vorhanden. Fragen Sie die
jeweilige Verkaufs-Abteilung.
ImPOrtAnt SAfety InStruCtIOnS
Read all instructions completely before proceeding.
DANGER: To reduce risk of shock:
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK. DO NOT OPEN
RISQUE DE CHOC ELECTRIQUE. NE PAS OUVRIR.
1 Always disconnect power from lift before cleaning.
WARNING–To reduce risk of burns, fires, electric shock or injuries to persons:
2 Disconnect power from lift before putting on or taking off parts.
3 Use this lift only for its intended use as described in these instructions. Do
not use attachments not recommended by the manufacturer.
4 Never operate this lift if it has a damaged cord or plug. If it is not working
properly, call your dealer or the manufacturer for assistance/repair.
5 Keep cords away from heated surfaces.
6 Never operate lift with air opening blocked. Keep the air openings free of lint,
hair, and the like.
7 Never drop or insert any object into any opening.
8 Do not use outdoors.
9 Route cords and cables as shown in the instructions.
WARNING: Rick of Electric Shock—connect this product to a
10
properly grounded electrical supply.
ImPOrtAnt InStALLAtIOn/OPerAtIng InStruCtIOnS
WARNING: To prevent injury, this apparatus must be securely attached to
the building structure in accordance with the instructions.
10 Test lift prior to installation. Please Note: Packaging must be removed from
lift before testing.
11 Follow instructions carefully. Installation contrary to instructions invalidates warranty.
12 Do not obstruct operation of Scissor Lift SLX with fingers or any object.
Serious injury or damage could result.
13 Lift is intended for use with product weighing not more than 150 kg.
14 Scissor Lift SLX is designed to accommodate ceiling suspended equipment.
equipment should not be allowed to rest on optional ceiling closure
during operation (refer to section titled "Installing Projector").
15 Entire bottom of unit must be unobstructed to permit proper operation.
Sufficient clearance must be allowed below projector or optional ceiling closure:
305 cm for Model SLX10, 427 cm for Model SLX14, etc.
16 Unit must be installed level (use a carpenter's level).
17 Unit operates on 230V AC 50 Hz. current. 5.4 amps current draw (2 amps for
lift, 3.5 amps for outlet).
18 Verify the show position when testing lift. Make required changes by referring
to adjustment instructions on page 4 of this document.
19 The maintenance/service factory limit setting must not be adjusted to a lower posi-
tion than the preset factory limit setting. In addition, Draper does not recommend set-
ting show position at the maintenance/service position—for example, if you wish to
have 244 cm show position, order a lift with at least a 305 cm maintenance position.
20 When the Scissor Lift SLX is to be installed in "other space used for environ-
mental air" the optional environmental air space housing must be installed per
instructions to isolate the lift from the "other space used for environmental air."
CAUTION: Before servicing unit, disconnect hardwired control and any
remote control.
Note: Unit has been thoroughly inspected and tested at factory and found to be
operating properly prior to shipment.
Electrical Connections
Unit operates on 230V AC, 50 Hz. current. 5.4 amps current draw (2 amps for lift,
3.5 amps for outlet).
Opening the electrical box exposes terminals for field connections. Unit is shipped
with internal wiring complete.Wire to connect unit to power supply should be
furnished by installer. Connections should be made in accordance with wiring
diagram, and wiring should comply with national and local electrical codes. An
appropriate disconnect device shall be provided as part of the building installation.
All operating switches should be "off" before power is connected.
Caution: Make sure electrical supply has been disconnected before
attempting to connect Scissor Lift to electricity.
Scissor Lift should be operated and checked prior to installing projector and/or
optional ceiling closure.
Low Voltage Control Switch shown below comes with 22.8 m of non-plenum rated
Copyright © 2014 Draper Inc. Form ScissorLiftSLX-230V_Inst14-R Printed in U.S.A.
Installation/Operating Instructions
Caution:
cable and should be plugged in to Control Panel on top frame of lift for control of
the "Up" and "Show" positions. Momentary Key Switch shown below comes with
22.8 m of cable and should be plugged in to Control Panel on top frame of lift for
control of the "Service" position.
LVC-S
Up & Show
2¾"
4½"
Front
1 Based on screen location and projector specifications, determine proper
position for projector installation.
2 Confirm that there is adequate space for installation and operation. Minimum
clearance above ceiling level varies according to Scissor Lift model, plus height
of projector, optional mounting bracket, optional ceiling closure, and optional
Environmental Air Space Housing.
3 Arrange to provide service access to the unit.
4 Maximum lifting capacity is 159 kg.
As Soon As Scissor Lift Arrives
1 Open carton and inspect for damage.
2 Locate the following parts:
A. The unit itself
B. Controls
C. Optional equipment: Environmental Air Space Housing, Universal
Projector Mount, closure panel or ceiling finish kit (all ship in separate
cartons).
3 Test lift prior to installation. Please Note: Packaging must be removed from
lift before testing.
Operation
Before operating or testing the unit, make sure the packaging has been
removed from the unit. This can be accomplished by removing the eight screws
(four per side) holding the packing frame to the lift. Once the packaging is all
removed, operate the lift in the "Up" direction, so the lift's control encoder will
recognize it's "home" location. Until you do this, the Down function will not work.
When unit is first operated, be cautious! If unit fails to operate properly, press
"off" and recheck electrical connections before proceeding. Cycle unit down and
up several times to confirm satisfactory operation. You must also do this if the
Scissor Lift ever loses or is disconnected from the power.
Caution: Do not pull on or touch safety belt when unit is in motion. If belt
locks, the cables will unspool.
Caution: Obstructing bottom pan may cause cables to unspool.
Standard Single Station Low Voltage Control (See Fig. 1)—One three-button
switch with "Up", "Down", and "Off" buttons. Lift starts up or down when appropriate
button is pressed, and may be stopped by pressing "Off" button. Factory set
limit switches stop lift automatically when projector is in "show" position. One
momentary key switch lowers lift from "Show" to "Service" position.
Optional Multiple Station Control—Optional, moves lift from "Stored" to "Show"
position only. Each switching station has a three-button switch with "Up", "Down",
and "Off" buttons. Lift starts up or down when appropriate button is pressed,
and may be stopped by pressing "Off" button. Factory set limit switches stop lift
automatically when projector is in "Show" position.
Optional Key Operated Switch—If ordered, the standard LVC-S can be replaced
with a second single station, momentary key-operated three position (up/off/down)
switch. Multiple Station Control required for this option. Moves lift from "stored" to
"show" position only.
Optional Infrared or Radio Frequency Remote Control—If ordered, a three-
button transmitter is provided, with "up", "down", and "stop" buttons. Unit starts up
or down when appropriate button is pressed, and may be stopped by pressing
"off" button. Factory set limit switches stop unit automatically when projector is in
"show" position. Only controls "show" and "stored" positions.
Optional RS232 Control—For Serial communication an R2D7 Serial
Communications Interface is optionally available.
Low Voltage Trigger—Input provided for Low Voltage
Trigger from projector (see diagram on page 4).
Please Note: Scissor Lift SLX must be installed in accordance with the
requirements of the Local Building Codes, the Canadian Electrical Code (CEC),
CAN/CSA C22.1 and the National Electric Code (NEC), NFPA 70, as required. An
appropriate disconnect device shall be provided as part of the building installation.
If you encounter any difficulties installing or servicing your Scissor Lift SLX, call your
dealer or Draper, Inc. in Spiceland, Indiana, 765-987-7999, or fax 765-987-7142.
SP-KSM
Service
7
/
"
8
OFF
OFF
UP
UP
DOWN
DOWN
D C U
Side
Back
Figure 1
Planning
Caution:
Beware of
pinch points