How To Replace The UV Light
1.
Before replacing the UV light, please unplug the unit.
2.
Lay the unit on its side and remove the screws of the UV light compartment under the base
of the unit.
3.
Remove the screw that is holding the wire harness.
4.
Use one or two flat tip screw drivers to depress the clip on each side of the UV light holder.
5.
Remove the old UV light and insert the UV light into the unit, making sure not to touch the
glass part of the bulb with you bare fingers as it can lower the life of the bulb.
6.
Place the UV light holder back over the UV light and secure the screw for the wire harness.
How To Replace The Filter
1. Push down the filter cover tab and lift the filter cover off.
2. Pull out each used filter; the T300 has two filters that
should be replaced at the same time.
3. Take the new filter out of the plastic bag; distinguish the
front side from the back side of the filter. The front side
has the black foam layer, known as the prefilter, which
should be facing out when inside the unit, insert into the
air cleaner with the arrow pointing inward.
4. Insert the bottom of the filter cover first and then snap in
the upper part of the grill.
5. RESET the filter
indicator by holding
down RESET while the
unit is ON until the
illuminated bars
disappear. To reach the
button, use a pin or
extended paperclip.