5.2 Service Procedures

The following procedures provide instructions for component replacement and adjustment.

5.2.1 Replacing Magnets

Parts required: Refer to
Supplies required: Loctite
1. Using the appropriate Allen wrench, remove the fasteners from the Teaching Aid plate. Refer to
Figure
2. Remove the magnets that require replacement.
3. Place the new magnet(s) in the Teaching Aid plate.
4. Apply Loctite Primer 7649 and Loctite 262 to the fastener threads.
5. Insert the fasteners into the Teaching Aid plate. Using the appropriate Allen wrench, thread into
the magnet. Tighten to 12 in-lbs (0.8 Nm).
Socket Head
Cap Screw
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 USA • Tel: 919.772.0115 • Fax: 919.772.8259 •
Section 6—Serviceable Parts
®
Primer 7649 and Loctite 262, 3/32 (for 4-40 Socket Head Cap Screw),
torque wrench
5.1.
Figure 5.1—Adjustment or Installation of Magnets
Magnet
www.ati-ia.com