Outdoor Temperature Sensor Option 2 —
Outdoor Air Intake
Mount the sensor in the outdoor air intake by drilling a 1/4 inch hole within
12" of outside. Angle the hole towards the outside. Insert the temperature
sensor into the intake pipe until the sensor is at least 2" outside the
wall of the house. Seal the hole and secure the wire so it cannot be
accidentally pulled out. See Figure 4 for example installation.
CAUTION: electrical interference can cause erratic system operation.
•
Do not route temperature sensor wiring with building power wiring, next
to control contactors, near light dimming circuits, or electric motors.
•
Use shielded cable to reduce interference when rerouting is not
possible.
•
Be sure wires have a cable separate from the humidistat cable.
•
See Figure 5 for wiring diagram.
Drill Hole in
Pipe & Seal
Connect to
Humidistat
(ODT)
Figure 4: Outdoor Temperature Sensor in Furnace Intake Pipe
Form 16763
RESIDENTIAL HUMIDISTAT
INSIDE
|
OUTSIDE
Furnace
Fresh Air
Intake
OAT (Outdoor
Air Temperature)
Sensor
2" min.
Installation
9