3.
Before installing the bracket, all position rulers should be checked first, and they
should be in the zero position, otherwise, the fixing bolts should be loosened first,
and set to zero. Adjust the bracket so that the four fixing bolts are in the middle of
the chute to ensure that the bracket can move in all directions.
Note: The bracket used in the side burn installation method and the bottom burn
installation method is not the same (as shown in the figure 2)
4.
Fix the bracket on the steel structure. Allow the sealing plate to fit perfectly to the
burner brick. Use a positioning tube (sold separately) to position the bracket so that
the bracket can be installed in such a way that the sealing plate and the burner block
are concentric, and can be fitted without gaps with the burner block. Secure the
bracket so that it cannot be easily moved.
5.
Move the burner bracket backward so that the seal plate and burner block are not
pushed, and there will be no force between due to thermal expansion during
furnace heat-up.
6.
Use thermal insulation fiber to plug the burner block hole to prevent the heat in the
furnace from releasing out.
7.
During furnace heat-up process, both the steel structure and the refractory block
will move due to expansion, and the burner holder needs to be readjusted.
8.
Move out the insulation fiber from burner seal plate and burner block.
9.
Before the furnace is ready to run, move the burner bracket forward so that the
center of the hole of the seal plate and the burner block is completely touching each
other, and the convex ring of the seal plate can fully enter the groove of the burner
block to ensure that the seal plate and the burner block are completely fitted.
Lack of cooling air will greatly reduce lifetime of the burner tip, gasket
6.2
Burner bracket fixing in position
1.
Use the positioning tube (to be purchased separately) to position the bracket so that
the installation position of the bracket can ensure that the burner is concentric with
the seal plate and can be fitted with the seal plate without gap. After confirming
that the installation position of the bracket is basically the same as the drawing,
proceed to the next step, Otherwise, adjust the position of the burner bracket on
the steel structure.
2.
Bracket position adjustment: Visually adjust the bracket position and height so that
the positioning tube on the bracket is concentric with the burner brick hole. Be
careful to keep the height of the bracket in the middle of the adjustment mechanism,
and determine the height of the support beam.
3.
Push the bracket forward until the front end of the positioning tube is close to the
Anderson Thermal Soluions(Suzhou)Co., Ltd
Anderson Thermal Solutions –FFA10 Burner Operation Manual
Warning
seal plate!
8