A watertight test has to be performed 60 minutes after the end of installation
or later.
Please be sure that all parts of the CYPRES are well prepared:
- the CYPRES is checked and fullfills all installation criteria (page 4)
- the filter of the housing is correctly installed (step 3)
- the housing containing the CYPRES processing unit is sealed with
the gasket and silicone (step 4 to step 14)
- the control unit cable splice seal, if existing, is not damaged
- the control unit seal is not damaged
- the plug connection seal of the field replaceable cutter is not
damaged
- the sealing of the lower end of the cutter is not damaged.
Ensure that the CYPRES is
Take a container with a diameter minimum 35cm and fill it with a minimum of
10cm water.
Fill the supplied syringe with approx. 5 cm³ air. Connect the syringe with the
filter of the water resistant housing using the supplied transparent tube. Put
the supplied little black adapter (consisting of a piece of PE tube) between the
filter and the transparent tube.
Instruction Manual CYPRES Water Resistant Kit
II Test Procedure
16.
17.
18.
Airtec GmbH
switched
off.