Airtec CYPRES 사용 설명서 - 페이지 13

{카테고리_이름} Airtec CYPRES에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Airtec CYPRES 17 페이지. Water resistant kit

Place the water resistant housing containing the switched off CYPRES and all
cables, the cutter and the sealed control unit into clean water. Remove any
bubbles sticking to the case by moving the case around in the water.
Carefully observe the unit under water for a period of 15 minutes.
Should any rising bubbles appear (especially at the cable entrance
section), a leak is indicated! In this case the unit should be removed
from the water immediately. Dry all parts thoroughly, open the housing,
remove the CYPRES and put it in a dry place.
Remove the silicone on the housing with the supplied brush and one
of the alcohol-pads. Prepare a new gasket, and repeat the whole
procedure from step 1 to step 20.
Please note that the air pressure inside the case may move the top of the
case. If this happens and, within a few seconds of placing the case under the
water some small bubbles appear at the gasket on the longer sides of the
case, it is okay. This does not mean that the casing is leaking. Because the air
pressure inside is higher than the water pressure outside, only the air can
leave the case, water cannot get inside.
This is the normal physical pressure compensation under water. When the
pressure inside the case and the water pressure outside is compensated, the
top of the case will set down closely on the gasket again. No more bubbles will
appear.
Instruction Manual CYPRES Water Resistant Kit
19.
20.
IMPORTANT!!
Airtec GmbH
page 13