Carolina Cooker M110836 소유자 매뉴얼 - 페이지 12
{카테고리_이름} Carolina Cooker M110836에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Carolina Cooker M110836 18 페이지. Cast iron stove (double burner)
This appliance was not designed
WARNING
!
for, and should not be connected
to, a natural gas supply line.
4. Make sure both shut-off valves are closed and
connect an LP cylinder, as described in section "5.2
Connecting the LP Cylinder" on page 9.
5. Remove the protective cap from the LP cylinder
valve, if installed, and connect the hose and gas
regulator assembly to the LP cylinder.
Be careful not to cross thread the
NOTICE
connector onto the valve. Hand tighten
only. Do not use tools to tighten this connection.
6. Make sure the hose is not kinked and is routed
away from any sharp edges or hot surface. The
LP cylinder should be placed at least 24 inches
away from the appliance.
The supply hose can be a trip
WARNING
!
hazard. Tripping over the gas
supply hose can cause spillage of hot oil or food,
resulting in serious burns. Place the LP cylinder away
from human or pet traffic. Do not walk between the
appliance and the LP cylinder.
7. Perform the Soapy Water Test described in the
following section to check for leaks.
5.3 Soapy Water Test
SAFETY INSTRUCTIONS
• The soapy water test must be performed outdoors
in a well-ventilated area.
• Do not perform the test around open flames, sparks,
lit matches, lighters, or cigarettes.
• Never use an open flame to test for gas leaks.
Model M110836
January 2021
The "soapy water test" must be performed each time:
• the LP cylinder is reconnected, or
• any time the appliance has been moved, or
• at least once per year and/or the appliance has not
been used for more than 60 days.
1. Remove any cookware or oil vats from the appliance.
2.
The shut-off valves and the LP cylinder valve
should be in the OFF or closed position.
3. Prepare a soapy water solution by combining one
part dish washing liquid with three parts water.
4.
Open the LP cylinder valve.
(with the shut-off valves in the closed
position).
5. Apply the soapy water solution to ALL
connections between the LP cylinder and the
shutoff valves on the manifold assembly.
WARNING
!
tighten the loose connection and repeat the test.
6. If leaks are identified between the LP cylinder
and the unit's shutoff valves, immediately turn
OFF the LP cylinder valve.
7. If connections are leak-free, continue to Step 10.
8. All connections with evidence of leaking should
be tightened, then repeat Steps 4 and 5.
9. If after tightening any loose connections bubbles
continue to appear, close the LP cylinder valve,
disconnect the LP cylinder, and do not use the
appliance. Contact the local retailer where the
appliance was purchased.
10. Continue with the Lighting Instructions or if the
appliance will not be used immediately, close all
gas valves and disconnect the LP cylinder.
10
Close the LP cylinder valve im-
mediately if bubbles appear. Re
Carolina Cooker®
844-478-4334