10.
The shutoff valves and the LP cylinder valve
should both be in the OFF or closed position.
6. Maintenance
6.1 Maintenance Safety
Failure to follow these safety instructions and warnings
could result in a fire or an explosion, which could cause
property damage, personal injury, or death.
WARNING
!
Damaged Parts Hazard
Do not use the appliance if any parts are damaged.
If the appliance has any type of defect, immediately
stop using it and remedy the problem before continuing.
Improper Maintenance Hazard
Improperly maintaining the appliance can cause a
malfunction, which can result in serious injury or
death. Always perform a per-operation inspection of the
appliance before use and correct any problems found.
Use Only Approved Replacement Parts
Use only approved replacement hoses, valves,
or regulators.
Maintenance Guidelines
1. Regularly inspect the burner for cracks, abnormal
holes, and other signs of significant corrosion or rust
damage.
a.
The burner is constructed of cast iron and steel
and may rust as a result of the extreme heat and
splatter from acidic foods.
b. Wire brush the outer surface of the burner to
remove buildup of food particles, dirt, or other
cooking residue.
Model M110836
January 2021
11. Close all gas valves and disconnect the LP cylinder.
12. Replace the protective LP cylinder cap when the
tank is not connected.
c.
Outward surface rust does not affect the use of
the appliance.
d. Do not tamper with or attempt repairs on the
burners. Replace damaged burners with new
OEM parts.
e.
Unauthorized modifications will void the
warranty.
2. If the burner is hard to light or does not appear to
be working correctly, check for an internal
obstruction or replace the burner assembly.
WARNING
!
proper gas mixture inside the burner, resulting in a
burner tube fire.
3. Inspect the inside of the burner tube for blockage
caused by insects or other small animals and/or
outdoor debris such as leaves, grass, etc.
To remove any blockage:
a.
Close the LP cylinder gas valve and shutoff valve.
b. Use a narrow bottle brush or a stiff wire to re
move any blockage.
12
Obstruction of combustion and
ventilation airflow can prevent
Carolina Cooker®