AUTO KISAN INSALLATION INSTRUCTIONS
3. Call rejected/SMS blocked by AutoKisan:
4. Manual OFF/Fuse OFF SMS:
5. Phase imbalance SMS:
ATISAYA ENGINEERING SERVICES
H.No. 12-1-28/B/N, Vijaya Gardens, Nagole, Bandlaguda Main Road, Hyderabad,
500068, India
a) Check whether the number you are
calling from is the registered Owner or
User.
b) If the number is registered Owner or
User. Try to reset the AutoKisan using
RESETxxxxxxx (replace 'xxxxxxx') with
your 7 digit pass code.
c) Then re-register your AutoKisan using
RNxxxxxxxxxx as mentioned in instruction
manual.
d) Check whether the issue is resolved. If
not resolved, contact service center.
a) Try to switch ON the motor using your
phone.
b) If you are getting Manual OFF/Fuse OFF
SMS go to the starter location and check
the fuses.
c) If fuses are good, check the current
sensing coils and its wires for any physical
damage. If there is any damage, consult
service center with the photos of it.
d) If the coils and wires are good, open the
AutoKisan cap and take a photo of its
internals then report to service center
with the photos.
a) Try to switch ON the motor using your
phone.
b) If you are getting Phase Imbalance SMS
go to the starter location and check the
voltage between fuses.
c) The voltage between fuses should be
nearly equal. If the voltages are not equal
then wait until voltages are stabilized.
d) If the multi meter is not available for
checking voltages, then wait for few
hours then try to switch on the pump
again.
e) If the issue is not resolved, consult an
electrician and ask him to check voltages
between the phases.
f) If the voltages are good, open the
AutoKisan cap and take a photo of its
internals then report to service center
with the photos.