Dresser DCR Series 설치 매뉴얼 - 페이지 10
{카테고리_이름} Dresser DCR Series에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dresser DCR Series 16 페이지. Rcs actuators
REQUEST A QUOTE AT WWW.AUTHORIZEDPARTS.COM
MA8 & MAR8 Parts List & Technical Data
7
2
8
9
13
4 Switch Option
1.50 Sq.
.75
.279
.281
Across
OSS Flats
Technical Data
Voltage: 115 Vac 60/50 Hz., 1 Phase—Standard
Operation: MA4 & MA8 Unidirectional MAR8 Reversible
Limit Switches: 5 Amps at 125 and 250 Vac UL &
CSA Listed
Ambient Temperature: -40°F to +150°F.*
Lubrication: High temperature grease for gears;
Self-lubricating bearings
Mounting positions: Universal
Weight: 3.5 lbs.
* The addition of a heater is recommended for all outdoor
installations and for all applications that are exposed to high
humidity or temperatures below 32°F. (Consult factory)
1
2
14
3
4
5
6
10-24 UNC-2B x .44 DP.
4 Places as shown
.438
ÿ
.437
1/2 N.P.T.
1.37
.82
Parts List
Loc. Description
No.
1
PC Board, 2 Sw.
1
PC Board, 2 Sw. + 2 ASWS
2
Spacer, 0.073 Long
3
Bracket
4
6-32UNC x 3/16 Long RHMS
5
Lock Washer
6
Capacitor
7
6-32UNC x 1/4 Long SSS
8
Switch Cam
9
Spacer, 0.19 Long
10
Spacer, 0.71 Long
11
Grounding Screw Bracket
12
Green Ground Screw
13
Spacer, 0.51 Long
14
Spacer, 0.135 Long
10
4.38 Sq.
1.25
2.19
2 Sw. 4 Sw. Part No.
Qty.
Qty.
1
–
177-068-42
–
1
177-068-44
2
4
24-532
1
1
62-118
2
2
P08-N06018-200
2
2
P51-N06000-0200
1
1
Per Order
4
8
P19-NO5025-0200
2
4
68-03
–
1
24-21
1
–
24-504
1
1
62-238
1
1
126A105719
2
2
24-16
1
1
24-70