Dresser DCR Series 설치 매뉴얼 - 페이지 12
{카테고리_이름} Dresser DCR Series에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dresser DCR Series 16 페이지. Rcs actuators
REQUEST A QUOTE AT WWW.AUTHORIZEDPARTS.COM
MAR10, 50 & 90 Parts List & Technical Data
2
7
9
14
13
17
15
.874/.875 Dia.
5/16-18 UNC-28 Thread.
3/8 Dp. (4-Places)
for Mounting
1.125
2.250 Sq.
Technical Data
Voltage: 115 Vac 60/50 Hz., 1 Phase—Standard
Operation: Standard Reversible (Unidirectional upon request)
Limit Switches: UL & CSA Listed–15 Amps & 1/3 HP, 125 or 250
Vac; 1/2 Amp, 125 Vdc; 1/4 Amp, 250 Vdc; 5 Amps, 120 Vac "L"
(Lamp Load)
Ambient Temperature: -40°F to +150°F.*
Lubrication: High temperature grease for gears;
Self-lubricating bearings
Mounting positions: Universal
Weight: 12.5 to 14.5 lbs. (depending on model)
* The addition of a heater is recommended for all outdoor
installations and for all applications that are exposed to high
humidity or temperatures below 32°F. (Consult factory)
1
6
3
4
5
8
3/4" N.P.T
3.28
7.83
.624/.620
Across Flats
8.00 Clearance for
Cover Removal
16
11
10
1.32
12
6.00
Parts List
Loc. No. Description
1
Knob – Manual
2
Retainer – Spring
3
O-Ring
4
Bushing
5
Shaft – Output
6
Push Rod – Declutching
7
Control Cover – NEMA 4
8
Terminal Strip
9
Cam
10
Cover Bolts 1/4-20 x 3/4
11
Gasket
12
Gear Case Assembly
13
Motor
14
Capacitor
15
Micro-Adjustment Plate
16
Limit Switch
17
Micro-Adjustment Cam
12
9.81
Manual
Position
9.41
(MAR10,
Auto
13, 25,
Position
50 & 90)
(MAR10,
15, 13,
25, 50
& 90)
7.41
(MAR9,
12, 24,
49 & 89)
.90
1.03
3.00
Qty.
Part No.
1
15-01-10
1
25-11
1
14-78
1
22-83
1
21-86
1
21-93
1
88-93
1
72-01/72-03
2 68-85-10
4
PO3-025075-3900
1
16-27
1
As Required
1
As Required
1
As Required
2
65-14
2
63-01
2
68-07