Wall drilling and bracket fixing
Wall marking:
• Draw a vertical line on the supporting wall up to the
ceiling, or as high as practical, at the centre of the
area in which the hood will be installed.
• Draw a horizontal line at 650 mm above the hob.
• Place bracket 7.2.1 on the wall as shown about 1-2
mm from the ceiling or upper limit align-ing the centre
(notch) with the vertical reference line.
• Mark the wall at the centres of the holes in the
bracket.
• Place bracket 7.2.1 on the wall as shown at X mm
below the first bracket (X = height of the upper
chimney section supplied), aligning the centre (notch)
with the vertical line.
• Mark the wall at the centres of the holes in the
bracket.
• Mark a reference point as indicated at 122 mm from
the vertical reference line and 280 mm above the
horizontal reference line.
• Repeat this operation on the other side.
• Drill ø 8 mm holes at all the centre points marked.
• Fix the lower bracket 7.2.1 using the screws.
• Fix the upper bracket 7.2.1 and the air outlet con-
nection support 7.3 together using 2 screws.
• Insert the two screws in the hood body fixing holes,
leaving a gap of 5-6 mm between the wall and the
head of the screw.
INSTALLATION INSTRUCTIONS
�����