Atlantic O'Pro 282029 설치 및 운영 매뉴얼 - 페이지 11

{카테고리_이름} Atlantic O'Pro 282029에 대한 설치 및 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Atlantic O'Pro 282029 17 페이지. Premium series mains pressure electric storage water heaters

Atlantic O'Pro 282029 설치 및 운영 매뉴얼
Maintenance by a qualified person
Remove the scale sludge. Do not scrape or chip at lime scale deposited
on the casing because this may damage the lining
Change the magnesium anode every 2 years or when its diameter is less
than 10 mm. Changing the heating element or the anode requires
the water heater to be drained and the seal changed.

Draining the tank

Turn off the power and the supply of cold water, open the hot water
faucets and manipulate the safety valve before performing these
operations. Refit the heating element and tighten the screws gently
(opposite screws in sequence), check for leaks the next day and
tighten if required.
If the supply cord is damaged, it must be replaced by a special cord or
assembly available from the manufacturer or approved service
agent.
Replaceable parts
Replaceable parts are the thermostat, seals, heating element, boiler
shell, indicator light, magnesium anode and connection cable. The
guarantee requires genuine manufacturer's parts to be used.
11