Atlantic FP500-75474 제품 설명서 - 페이지 4
{카테고리_이름} Atlantic FP500-75474에 대한 제품 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Atlantic FP500-75474 17 페이지.
• In case of excessive vibration, unusual noise or odor, turn off the power immediately and
consult your nearest dealer.
Maintenance and Inspection
• Regular maintenance and inspections are a necessity for continued efficient functioning. If
any abnormal conditions are noticed, refer to the section on Troubleshooting and take
corrective measures immediately.
Monthly Inspection / Cleaning
• Check for any drop in performance. Reduced performance is usually caused by debris
blocking the pump intake.
• Detach the power cable from the receptacle or turn off the power supply (circuit breaker).
• Disconnect the pump discharge and remove the pump from the water.
• Remove any accumulated debris from the surface of the pump and pre-filter.
• Remove the pre-filter, inspect the adjustable flow and remove any accumulated debris.
• Remove the threaded inlet cover by rotating it in a counterclockwise half turn while pulling
lightly outward from the pump body.
• Inspect the impeller and remove any debris that may be present.
• Spin the impeller. If the impeller is difficult to turn, feels "gritty", or a grinding noise is
evident in the rotor chamber, remove the rotor as per the instructions below.
Removing the Rotor
• Remove the impeller assembly by pulling outward from the rotor chamber.
Note: The impeller assembly is comprised of six individual parts shown in the image below.
Take care not to lose or misplace any of these pieces during the cleaning process.
Pre-filter
4
Threaded
Inlet Cover
Flow Adjustor
Rubber
Bushing
Friction
Washer
Ceramic Shaft
Rotor
Chamber
Impeller
Assembly
Rubber
Bushing
Friction
Impeller/
Washer
Magnetic Rotor
Pump Body/Motor
Rubber Feet