Atlantic Ultraviolet Nutripure 5B-SC 소유자 매뉴얼 - 페이지 11

{카테고리_이름} Atlantic Ultraviolet Nutripure 5B-SC에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Atlantic Ultraviolet Nutripure 5B-SC 16 페이지. Sanitary conditioners

Atlantic Ultraviolet Nutripure 5B-SC 소유자 매뉴얼

TROUBLESHOOTING

Always disconnect power to the Nutripure
Use personal protection equipment, such as gloves; long sleeves with no gaps between cuffs and gloves, and
ultraviolet resistant face shield, if troubleshooting Nutripure
IMPORTANT: This fixture is to be serviced ONLY by qualified, and appropriately licensed, personnel
Problem
Nutripure
®
not operating
Internal blower not
functioning
STER-L-RAY
®
Germicidal
UV lamp not operating
If the above measures fail to correct the problem(s) contact our UV Application Specialists. Contact options can be found in the
"User Assistance" section of this manual located on the back page.

REPLACEMENT PARTS

MODEL
STER-L-RAY
®
UV Lamp
with ArmorLite
TM
(QTY)
Surelite
Ballast: 120v
TM
50/60Hz
Surelite
Ballast: 220v
TM
50/60Hz
Blower: 120v
Blower: 220v
Promate
TM
Electrostatic Filter
Promate
HEPA Filter
TM
Tank Vent Filter
Table 1 – Troubleshooting
Possible Cause
No electrical power
Power connections, to fixture, loose or disconnected
Loose power connection
Faulty blower motor
STER-L-RAY
®
Germicidal Lamp inoperative
STER-L-RAY
®
Germicidal Lamp not properly seated
Table 2 – Replacement Parts
2B-SC
3B-SC
4B-SC
05-6011
05-6011
05-6011
(1)
(2)
10-0137
10-0137
10-0137
10-0136
10-0136
10-0136
40-0104A
40-1079B
40-0104A
40-0032A
40-0031A
40-0032A
40-7058B
40-7058B
40-9078B
40-7058B
40-7058B
40-9078B
®
before performing any service or maintenance.
®
.
Corrective Action
Verify that the fixture is connected to a live
power source.
Verify power connections to
fixture are fully engaged.
Confirm connection to blowers; connections are
tight and making full contact.
Replace blower motor.
Swap suspect lamp, with known
good lamp. If known good lamp does
not operate, replace ballast.
Confirm contact between lamp and lampholder
is tight and lampholder is making full contact
with lamp.
4B-ASC
5B-SC
05-6011
05-6011
(1)
(1)
(2)
10-0137
10-0137
10-0136
10-0136
40-0104A
40-1079B
40-0032A
40-0031A
40-9078B
40-9078B
40-1202A
40-9078B
40-9078B
5B-ASC
6B-SC
6B-ASC
05-6011
05-6013
05-6013
(2)
(4)
10-0137
10-0137
10-0137
10-0136
10-0136
10-0136
40-1079B
40-1078B
40-0020B
40-0031A
40-0078
40-0311A
40-9078B
40-1266B
40-1266B
40-1202A
40-0021A
40-9078B
40-1266B
40-1266B
(4)
11