Atlas Copco 8431035021 제품 지침 - 페이지 5

{카테고리_이름} Atlas Copco 8431035021에 대한 제품 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Atlas Copco 8431035021 12 페이지.

Atlas Copco 8431035021 제품 지침
W2621

Installation

Installation requirements

Air quality

For optimum performance and maximum product life we recommend the use of compressed air with
a maximum dew point of +10°C (50°F). We also recommend to install an Atlas Copco refrigeration
type air dryer.
Use a separate air filter which removes solid particles larger than 30 microns and more than 90% of
liquid water. Install the filter as close as possible to the product and prior to any other air preparation
units to avoid pressure drop.
For impulse/impact tools make sure to use lubricators adjusted for these tools. Regular lubricators
will add too much oil and therefore decrease the tool performance due to too much oil in the motor.
Make sure that the hose and couplings are clean and free from dust before connecting to the tool.
Both lubricated and lubrication free products will benefit from a small quantity of oil supplied from a
lubricator.

Air lubrication guide

Brand
Atlas Copco
Q8
Shell

Compressed air connection

WARNING Compressed air can cause serious injury
Always shut off the air supply, drain hose of air pressure and disconnect the tool from air supply;
when not in use, before making any adjustments to the product - for example changing acces-
sories, or when making repairs.
WARNING Whipping hoses can cause serious injury
Always make sure that there are no damaged or loose hoses or fittings.
WARNING Compressed Air
High air pressure can cause severe damage and bodily injury.
Do not exceed maximum air pressure.
Make sure that there are no damaged or loose hoses or fittings.
For correct air pressure and hose size, see section Technical data.
Make sure that the hose and couplings are clean and free from dust before connecting to the tool.
EN
© Atlas Copco Industrial Technique AB - 9839 0891 01
Air lubrication
Optimizer (1 liter) 9090 0000 04
Chopin 46
Shell Air Tool Oil S2 A 320
Installation
5