Service Pumps (continued)
Oil Change
Change oil after first 50 hours of use.
Then every 500 hours. Refer to parts
breakdown for oil type.
Servicing the Built-in Unloader
and Check Valve
These partw are serviced as assenbled
kits.
Tools required: 3/8" drive ratchet, 19mm
deepwell socket, medium strength
thread locker, needle nose pliers.
Check Valve Removal:
1.
Remove the chemical
injector discharge
nipple. Use the needle
nose pliers to lift out
the check valve. (See
Figure 29)
Check Valve Assembly:
1.
Place the check valve into the
discharge outlet with the pointed
side going in first (NOTE: older
model pumps have
springs that go into
the hollow portion
of the valve, newer
models do not have
springs.) (See Figure
30)
2.
Inspect the o-rings on the injection
nipple, if damaged
replace. Place small
amount of thread locker
on the thread and
tighten. (See Figure 31)
Unloader Removal:
Tools required: 3/8" rachet, 22mm deep
well socket, crescent wrench, small
hammer, 6mm x approximately 8mm or
longer, medium strength thread locker.
Unloader assembly removal:
1.
Using the 22mm
socket rotate the
pressure adjusting
cap so both set of
hexes are alligned.
Use screw to remove
the complete unloader
assembly. (See Figure 32)
1.
Screw the 6mm bolt into the
unloader piston seat, grab the bolt
with the crescent
wrench just under
the head. Using
the hammer tap
the bottom of the
Figure 29
wrench. The seat will pop
out. (See Figure 33)
Unloader assembly:
1.
Piston seat installation
screw the new seat
onto the bolt (NOTE:
the flat side is the
bottom). Push squarly
into the unloader base
and tap into place with
Figure 30
the hammer. (Remove
the bolt) (See Figures 34
& 35)
2.
Place a small amount
of thread locker on
the unloader cartride
threads and screw into the
base and tighten.
Figure 31
RSV Series Pumps