Anolis ArcPower 72/K2 사용자 설명서 - 페이지 6
{카테고리_이름} Anolis ArcPower 72/K2에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Anolis ArcPower 72/K2 20 페이지.
2.RJ45 patch cables category 5 that connect the ArcPower 7/K each other are wired 1:1,that is,pins with the
same numbers are connected together.
Pin 1: Not used
Pin 2: Not used
Pin 3: Not used
Pin 4: Not used
Pin 5: Not used
Pin 6: Data +
Pin 7: Data -
Pin 8: GND
5.Installing instructions.
Never connect 1W LEDs modules to the ArcPower 72/K2
5.1.DMX operating
1.Unplug from the mains before installation.
2.Connect the LED modules to the fixture.Make sure that all modules include Luxeon K2 LED´s.
3.Connect the DMX controller to the fixture
4.Connect the fixture to the mains
5.Set the DMX address on the control board of the fixture (see chapter "Control board").
6.Check the current limit setting "C.Li" in menu "SPE" (see chapter "8.6 Special functions").
Accidental connection DMX 512 Input/Output to non-DMX 512 device (e.g.Ethernet
Maximum total cable length between one LED zone output of the Arcpower 72/K2
Single ArcPower 72/K2 installation:
Warning!
network Hub) can damage the ArcPower 72/K2.
and all its connected LED modules is 40 metres.
6
Pin 1: Not used
Pin 2: Not used
Pin 3: Not used
Pin 4: Not used
Pin 5: Not used
Pin 6: Data +
Pin 7: Data -
Pin 8: GND