Drytac HOT PRESS HGP260 사용자 설명서 - 페이지 8

{카테고리_이름} Drytac HOT PRESS HGP260에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Drytac HOT PRESS HGP260 19 페이지. Heated glass top vacuum press
Drytac HOT PRESS HGP260에 대해서도 마찬가지입니다: 운영자 매뉴얼 (19 페이지)

Drytac HOT PRESS HGP260 사용자 설명서
HOT PRESS USERS MANUAL
A
T
DJUSTING THE
EMPERATURE
(F
)
AHRENHEIT
To adjust the pre-set temperature, press and hold Button 1. Then use Button
2 to increase or
2 to increase or
2
Button 3 to decrease the pre-set temperature. Once the
Button 3 to decrease the pre-set temperature. Once the
Button 3
desired level is reached, release Button 1 to set the desired temperature.
When current is fl owing through the heating element, a small red dot next
to OUT1 will glow. In normal operation, the dot will turn on and off every few
minutes as the controller maintains the glass at the preset temperature.
At the factory, the temperature controller is set to allow a maximum
temperature of 239°F. The factory preset temperature is 194°F.
A
T
DJUSTING THE
EMPERATURE
(C
)
ELSIUS
To adjust the preset temperature, press Button 1 and L1 will appear for one
second. Then press Button 3 to increase or
Button 3
Button 3 to increase or
temperature. Once the desired level is reached, press Button 1 to set your
required temperature.
When current is fl owing through the heating element, a small red dot next
to RL1 will glow. In normal operation, the dot will turn on and off every few
minutes as the controller maintains the glass at the preset temperature.
At the factory, the temperature controller is set to allow a maximum
temperature of 115°C. The factory preset temperature is 90°C.
Should you press Button 4 in error and HY1 displays, just press Button 1
again. Do not change the value that follows HY1.
C
ONTROLLER
C
ONTROLLER
Button 4 to decrease the preset
8

Temperature Controls

Illustration 8A: Temperature controller (F)
Illustration 8B: RL1 dot.