Daikin FTKS60KVM 서비스 매뉴얼 - 페이지 12

{카테고리_이름} Daikin FTKS60KVM에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Daikin FTKS60KVM 20 페이지. Removal procedure, 5.0/6.0/7.1 kw class, 15000/18000 btu/h class
Daikin FTKS60KVM에 대해서도 마찬가지입니다: 서비스 매뉴얼 (20 페이지)

Daikin FTKS60KVM 서비스 매뉴얼

PCBs

7. PCBs
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
1
Remove the screw on
the electrical box.
2
Unfasten the hook and
remove the shield plate.
3
Unfasten the 2 hooks
on the top and remove
the signal receiver unit.
10
All manuals and user guides at all-guides.com
Procedure
Electrical box
Shield
plate
Hook
Signal receiver
unit
Points
(R17747)
The shield plate also has 2
hooks on the upper side (at
the back).
(R13224)
(R2781)
Removal Procedure
Si041254EE