3M W-2806/07006 사용자 지침 - 페이지 15
{카테고리_이름} 3M W-2806/07006에 대한 사용자 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. 3M W-2806/07006 19 페이지. Compressed air filter and regulator panel
3M W-2806/07006에 대해서도 마찬가지입니다: 일반 작동 및 부품 지침 (2 페이지)
Wire Color
Detector Terminal
Black
CNTR
Blue
REF
Red
SENSING
Be sure flow block cavity and o-ring are dry
and clean of oils, dirt etc. The o-ring must be
positioned evenly in the bottom of the flow
block cavity. Push the sensor into block against
o-ring and evenly tighten the 2 screws that hold
the circuit board/sensor to flow block. Tighten
screws lightly to assure good seal with o-ring.
Do not overtighten screws or damage to circuit
board/sensor may occur.
Replace the bottom plate and secure it
with thumbscrews.
Make sure the inlet sample swivel elbow
is firmly tightened.
Allow at least one hour for stabilization,
then calibrate as in Calibration and Adjustment
section of this User Instruction.
14
Circuit board/
sensor to flow
block mounting
screws.
Wire connectors'
circuit board
"CO" sensor cell
O-ring
Flow block
Fig. 4