Step 3 – Item #01 House Code & Unit Number – ESCORT Section [130]
Each light module has dials for selecting a unique address for each. A unique address is required for each
light module so that the user can control them individually. One dial is used to select from letter [A] to [P],
the other dial is used to select a number from [1] to [16].
Referring to Appendix B, program the three digit code equivalent to the letter and number
corresponding to the letter and number selected for the first X-10 light module (i.e. [A1] = [000]).
Step 4 – Item #01 Miscellaneous Options – ESCORT Section [131]
Turn Option [01] ON to enable the X-10 module.
Turn Option [02] ON to enable end user manual control.
Option [03] allows you to select if the X-10 module will be included in global commands. For example,
several light modules may present to control downstairs lighting. At bedtime, rather than having to turn off
each light module individually, the user could initiate a 'global off' command. All the light modules
included in the global command option would be turned off.
Turn Option [03] ON to include the X-10 module in the global command group. Turn Option [03]
OFF to exclude the X-10 module from the global command group.
Turn Option [04] ON to enable dimming.
Turn Option [05] ON so that the light module will always turn on or off when scheduled to do so.
Turn Option [06] ON so that the light will remain on until told to turn off.
The Escort can be programmed to announce different words when an X-10 module is activated/deactivated.
Depending on the application, turn Option [07], [08] or [09] ON. Only turn ON one of these options. In
the case of lighting, it is logical for the Escort to announce 'on' and 'off'.
Turn Option [07] ON so that the ESCORT will announce the light is on and off when activated.
Turn Option [08] OFF.
Turn Option [09] OFF.
Step 5 – Item #01 Schedule Assignment – ESCORT Section [132]
Each X-10 module can be programmed to follow any or all of the 16 available schedules. In our
application, only one schedule is required.
Turn Option [01] to enable Schedule #01.
Step 6 – Item #01 Schedule/Output Condition – ESCORT Section [134]
Enter data [02] to enable schedule control.
Step 7 – ESCORT Schedule #01 Programming – ESCORT Section [030] to [032]
Each of the 16 schedules contain three program items; On time, Off Time and Day of the Week selection.
Program data [0800] in Section [030] (8:00 am On Time)
Program data [2000] in Section [031] (8:00 pm Off Time)
Turn Options [01] through [07] ON to enable all days of the week.