4. Configuration
In factory configuration, the movement
detector is configured in deterrence (for the
reactions of the system see the control panel
installation guide). It is possible to modify the
level of alarm using the following sequence
of parameter setting:
Configuration example:
setting the
detector for an alarm level when a prealarm
is triggered: Parameter n° 5, Parameter value
2.
Sequence of
Parameter n°
parameter setting
5
Indicator lamp
for
programming it
Indicator lamp
about 10 sec.
for programming
not lit
sequence
To start the
Press 5 times
sequence
depending
press and
on the required
hold the
parameter
button until the
number
LED indicator
lamp goes out
5
Start
Press 5 times
Press
to select
once to
the alarm
accept
level
selection
71
Alarm level
Parameter value
Intrusion
1
Prealarm
2
Deterrence
3 (factory setting)
Warning
4 (the feature is available using n e cl o sntrol pa
with 2.0.0 version software or later)
about
5 sec.
Press and
Press 1 to 4
To end the
hold until the
times depending
sequence press
LED
on the required
and hold the
indicator
parameter value
button until the
lamp briefly
LED indicator
goes out
lamp goes out
2
about
2 sec.
Press 2 times
End
to select
the preal
level
GB
about 10 sec.
about
2 sec.
LED indicator
lamp lit =
correct
configuration