5. Installing the detector
IMPORTANT: make sure there is a distance of at least 2 meters between each product, except between two detectors.
5.1 Choosing the best place
The motion detector must be placed:
• inside the building,
• 2.20 m above ground level
• at right angles to the entrances to be protected
(interior detection works best when the intruder walks
across the detector's fields-of-view),
• directed towards the inside of the room to be
protected,
• in such a way that the area it protects does not
overlap with that of another motion detector.
The motion detector must not be placed:
• in an area likely to receive direct sunlight or a very
powerful light source,
• opposite or above a source of heat,
• outside or in a breezy place,
• directly on to a metal wall or close to sources of
interference (electricity meters, etc.) or ventilation
such as air-conditioning grilles.
RIGHT
RIGHT
78
WRONG
WRONG