DAITEM SH272AX 설치 매뉴얼 - 페이지 2

{카테고리_이름} DAITEM SH272AX에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DAITEM SH272AX 8 페이지. Multicontact detector

2. Preparation
Opening
1. Loosen the screws using a
cross-head screwdriver.
2. Unclip the base plate cover.
Pozidriv 2
Power supply
The lithium battery pack is clipped into position (see diagram below). An arrow
indicates which way to connect it.
When switched on the detector performs a self-test. If the self-test is:
• correct, the LED indicator lamp lights up for 2 sec.,
• incorrect, the LED indicator lamp flashes every 5 sec.
3. Programming
IMPORTANT: during recognition programming, the product to be programmed for use with the control panel does not need to
be placed next to it. In fact, we recommend you place the product at a short distance from the control panel (at least 2 meters
away).
Programming enables multicontact detectors to be recognised by the control panel.
1. To programme multicontact detectors the control panel must be in installation mode. If it is not, you will require the
user's master code, press:
master code
(0000 factory default)
2. Programme the device as follows:
then
Press and hold the "test"
Press
then
#
on
*
button until the control
the control panel
panel responds
keypad
IMPORTANT: the control panel indicates an error by emitting 3 short beeps. When this happens programming should be
carried out again.
then
engineer installer code
(1111 factory default)
"detector X"
"group?"
10 s max.
* according to the
The control panel waits
for a group to be chosen
(from 1 to 8)*. Choose the
groups by pressing the
corresponding numeral on the
control panel keypad
Guarantee sticker
Remove the pre-cut part of the sticker and stick it to the
guarantee certificate in the user manual supplied with
the control panel. If you are adding the siren to an
existing system, use the guarantee sticker provided with
this product.
SH271AX
SH271AX
"beep, installation
"time delay?"
*
to
to
type of control panel
Choose the type of triggering:
0: immediate
1: delayed
2: combined
Use the control panel keypad
to select the type
2
Connection terminals
for external contacts
Alignment arrow
Lithium battery
mode"
"beep, detector X,
group Y immediate
(or delayed
or combined)"
The control panel
gives a voice
message to confirm
detector programming