• Example: programming of 1st detector allocated to Group 2 with immediate triggering.
then
10 s max.
4. Configuration
IMPORTANT
• The cover must be open when configuring the detector.
• An unused built-in or external contact must be configured as inactive.
Configuring the multicontact detector
enables the characteristics of the 2
contacts (built-in and external) to be
defined.
To configure the contacts:
• choose the parameter number
corresponding to the Contact Type to
be configured,
• choose the parameter value
corresponding to the characteristics
of the contact to be configured.
Follow the configuration sequence described below:
about 10 sec.
To start the sequence
Press 1 or 3 times
press & hold the button
depending on the
until the LED indicator
required parameter
lamp goes out
Configuration example: configuring the multicontact detector with an external contact (Parameter n° 3) connected to a
wide gap normally closed contact (Value 2). An intrusion alarm is generated when the garage door is opened.
Start
Press 3 times to select
the external contact
"detector 1"
"group?"
Type
Parameter Contact characteristics
of contact
Built-in
External
about
1 or 3
5 sec.
Press & hold
until the LED
indicator lamp
number
briefly goes out
3
Press once to
accept selection
"time delay?"
"beep, detector 1
group 2,
immediate"
IMPORTANT: the control panel indicates
an error by emitting 3 short beeps.
When this happens programming should
be carried out again.
n°
1
inactive
active (NC) (factory setting)
3
inactive (factory setting)
normally closed contact (NC)
roller shutter blind sensor
normally closed contact
for roller shutter blinds
piezo-electric glassbreak
sensor (NC)
shock sensor (NC)
pressure mat (NO)
other external contacts (NC)
1 to 9
Press 1 to 9 times
To end the sequence
depending on the
press & hold until the LED
required parameter
indicator lamp goes out
value
2
Press 2 times
to select
the NC contact
3
Parameter Supervised
value
opening
1
no
2
yes
intrusion
1
no
2
yes
intrusion
3
no
intrusion
5
no
6
no
intrusion
7
no
8
no
deterrence
9
no
deterrence
about 10 sec.
about 2 sec.
LED Indicator
lamp lit =
correct
configuration
End
Alarm
level
-
-
prealert
prealert