DSC 3g4000 설치 매뉴얼 - 페이지 4
{카테고리_이름} DSC 3g4000에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DSC 3g4000 8 페이지. 3g (hspa) wireless alarm communicator
Ratings
Power Supply Ratings
Input Voltage (Nominal):. . . . . . . . . . . 9-14V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.8V
Input Current: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500mA (9-14Vdc) or 700mA (13.8V
Current Consumption
Average: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40mA*
Peak (no battery): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180mA*
Peak (with battery): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350mA*
* Plus any current drawn from the 3G4000 + terminal
Battery: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NiMH, rated 7.2V, 2.2Ah
Battery charging voltage (maximum): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.1V
Battery charging current: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60mA
NOTE: Battery must be replaced every 3-5 years.
Operating frequency: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 850/1900MHz
Antenna gain: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.0dBi
Environmental Specifications
Operating temperature: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C-49°C (32°F-120°F)
Humidity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93%RH Maximum (non-condensing)
Mechanical Specifications
Dimensions (plastic enclosure, painted): . . . . 125 mm (W) × 220mm (H) × 31mm (D) / 4.9" × 8.7" × 1.2"
Weight (without battery): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .400g / 1.2oz
Simulated Telco Loop specifications (TIP/RING)
On-Hook Voltage: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12V
Off-Hook Voltage (maximum): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22V
Loop Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25mA
Loop Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .600 Ohms
This equipment (3G4000) is fixed and shall be installed by Service Persons only (Service Person is defined as
a person having the appropriate technical training and experience necessary to be aware of hazards to
which that person may be exposed in performing a task, and of measures available to minimize the risks to
that person or other persons). It shall be installed and used within an environment that provides the
pollution degree max 2, over voltages category II, in non-hazardous, indoor locations only. This manual shall
be used with the Installation Manual of the relevant alarm control panel. All instructions specified within that
manual must be observed.
C24 Communications Enrolment
The 3G4000 requires enrolment with C24 Communications to operate. For more information, please visit
www.connect24.com, contact C24 Communications customer service at 1-888-251-7458 (US) / 1-888-955-
5583 (Canada) or contact the central station to inquire if they are a C24 Communications Master Reseller.
NOTES: Enrollment with C24 Communications should be performed before turning on the 3G4000 unit.
Before inserting or removing the SIM card, please ensure the unit is turned off.
STEP 1 - Initialize the 3G4000 with C24 Communications
The 3G4000 can be initialized with C24 Communications by:
web - www.connect24.com
mobile - m.connect24.com
To complete enrolment, a C24 profile, installer ID/PIN (or web credentials) and the 20-digit SIM number are
required.
NOTE: The SIM activation process with the cellular carrier typically takes between five and ten minutes
to complete.
STEP 2 - Determine the Best Signal Location
1. Remove the front cover by inserting a screwdriver into each of the slots at the bottom of the enclosure
and pushing down.
2. Apply power (DC and/or battery). The 3G4000 is now in placement test mode.
STEP 2a – SIM card is activated.
The red LED will be on solid, the blue LED will be off and the signal strength LEDs will display the average
signal strength. In this state, the 3G4000 is registered to the cellular network.
(use separately listed control panel or power supply) or
DC
Installing the 3G4000
(use DSC ADP1320-NAx power adapter)
DC
2
)
DC
DC
DC
DC