E32
1. Please check if speed sensor's plug is well connected to the mainboard.
2. If it is well connected, please change the speed sensor with the normal sensor.
3. Check the disk and make sure it is not deformed. If it is deformed, please change the disk.
4. If it is still not working, then change the mainboard.
E30
1. Please make sure there is no object covering the sensor.
2. Please check if the stacker sensor's plugs, which are in pairs, are all well connected to the
mainboard.
3. If they are well connected, please change them one by one using the normal sensor and
check if they can work.
4. If all sensors are changed but still not working, please change the mainboard.
E29
1. Please make sure there is no object covering the sensor and to not have it directly under
strong light.
2. Please check if the hopper sensor's plug is well connected to the mainboard.
3. If it is well connected, please change it with the normal sensor and check if it can work.
4. If all sensors are changed but still not working, please change the mainboard.
Alarm Codes
E17
1. Detects suspicious fake notes by using the UV method.
2. A real banknote which had been washed might also cause E-17 to go off.
3. If the note is real, the UV sensor might be damaged, so change the UV sensor.
4. If the note is real, the mainboard might be damaged.
E18
1. Detects suspicious fake notes by using the MG method.
2. A real banknote which had been washed or has the magnetic thread damaged might also
cause E-18 to go off.
3. If the note is real, the MG sensor might be damaged, so change the MG sensor.
4. If the note is real, the mainboard might be damaged.
E11
1. Double notes that stick together might cause E11 to go off.
E23
1. Check the hopper setting to see if the hopper screw might need to be tightened.