WIRING THE ALARM RELAY OUTPUT
The ES8108 has a built-in alarm-relay for port link and power events
notifications. The relay contacts are normally open and remain open when
there is no failure event. The relay contacts close when there is a failure
event to notify.
The failure events are selectable and enabled using the DIP switch on the
ES8108. The relay contacts of the ES8108 are rated for a maximum of 0.5A at
24VDC.
1.
Insert positive and negative wires into V+ and V-.
2.
Tighten the wire-clamp screws to prevent the wires from coming loose.
WARNING - Exposure to some chemicals may degrade the sealing properties
of materials used in the sealed relay
SETTING THE DIP SWITCH
Switch
Status
1 to 8
ON
(Port)
OFF
9
ON
(Power)
OFF
Maximum 0.5A/24VDC
Alm
PW1
PW2
Alarm Control
port 1~8
Description
Enables port link down alarm for the corresponding port
Disables port link down alarm for the corresponding port
Enables the power failure alarm
Disables the power failure alarm
Alarm
System
Extra Power
System
power