Anyload NPS Series 운영자 매뉴얼 - 페이지 5
{카테고리_이름} Anyload NPS Series에 대한 운영자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Anyload NPS Series 12 페이지. Pallet jack scale
4.3 RS232 Connection
RS232 connection with printer or computer applies only to T15E-R, T15C-R,
T15E-A, T15C-A indicator models:
1. Serial communication interface use RS232 plug with 9 cores.
2. All data are in ASCII codes. Every set is composed of 10 bits: the
st
1
3. Baud rates: 2400/4800/9600/19200
4. Communication Type: Command Mode
2- pin = Data output (TXD)
5- pin = Ground (GND)
4.4 Printer Connection
Printer pin 1 connects with +5V
Printer pin 2 connects with GND
Printer pin 4 connects with TXD
Printer pin 5 connects with GND
4.5 Display
1. Zero status indication. Will light on when the scale is at the centre of
its zero band.
2. Indication when battery charge is low
3. Tare status indication. Will light on when the weight has been tared.
4. Will light on when the scale is in Counting Mode
5. Will light on when the scale is set to lb unit of measurement
6. Will light on when the scale is set to kg unit of measurement
4 |
ANYLOAD NPS Series Pallet Jack Scale Operator's Guide (V1906) – T15E v2 series indicator
is the starting bit, the 10
th
is the stop bit.