6.

Maintenance

1) To ensure long term usage with accurate and stable output, please
use reliable power supply
2) Do not adjust the SPAN potentiometer ( of calibrated amplifier ) by
inexperienced personnel
3) The amplifier can only support up to 8 load cells with 350 Ohms
each or combination of multiple load cells with equivalent power
consumption for 8x350 Ohms load cells
7.
Warnings & Precautions
1) To avoid damaging the interface, finish the wiring first then connect
the 24VDC supply
2) For safety purposes, supply the 24VDC power by connecting the
positive power terminal first, then the negative power terminal (
common )