[Troubleshooting]
If the followings are displayed on the LEDs of this product, take
measures as shown below.
LINK
IN
ALM
○
○
○
Off
Off
Off
●
○
○
On
Off
Off
◎
○
◎
Flashing
Flashing
Off
(0.5 seconds
(0.5 seconds
alternately)
alternately)
-
-
◎
Flashing
(On for
0.2 seconds,
off for
1.0 seconds)
◎
-
●
Flashing
On
◎
-
◎
Flashing
Flashing
(0.1 seconds
alternately)
When the following error is indicated on the address writer, take
measures as shown below.
Indication
Cause
[E-0303]
The set parameter is incorrect.
Take measures as follows in the following case.
Symptom
Detection cannot be
- Is the detected metal in the appropriate location?
performed.
→ Make adjustments so that the detected metal is within an appropriate range
from the ASLINKSENSOR detection surface.
- Is wiring correct?
→ Con rm that the ASLINKSENSOR transmission line is correctly connected
to the AnyWireASLINK transmission line (DP, DN).
- Are the AnyWireASLINK master unit and slave unit powered by a power supply
with the appropriate capacity?
→ Con rm the power supply.
- Did you perform teaching?
→ Perform teaching settings with the work that is actually detected.
- Are you using within the rated detection range?
→ Use within the rated range.
Setting cannot be
- Is wiring correct?
performed with
→ Recon rm the ASLINKSENSOR transmission line connection.
the address writer.
- Is power fed to the AnyWireASLINK system?
→ Con rm the power supply.
- Is the set parameter correct?
→ Check the parameter and set the correct parameter.
[Parameters and items]
Parameter
Variable
[01.]
Threshold
Set the threshold of the sensing level
0 - 100%
to judge presence/absence of detection.
[02.]
0 - 100%
Set change amount of sensing level
Hysteresis
required to turn detection state ON to OFF.
[03.]
Set an upper limit for the alarm
0 - 100%
Alarm value Hi
judgment value.
[04.]
Set a lower limit for the alarm
Alarm value Lo
0 - 100%
judgment value.
[05.]
Set a monitor time for the alarm
Alarm value
3-255
judgment value. (1 = 100ms)
monitor time
[06.]
0
Normally open
Normally open/
1
Normally close
Normally close
[07.]
0
Simple mode
Operation
1
Normal mode
mode
[10.]
0
Delay timer disabled
Delay timer
1
ON/OFF
ON delay timer
2
OFF delay timer
3
ON/OFF delay timer
[11.]
Delay timer
0 - 255
Set the delay time. (1 = 10ms)
value
Cause
Measures
- ASLINKSENSOR is
- Con rm that there is no
not connected to an
disconnection between the
AnyWireASLINK
ASLINKSENSOR and the
system.
AnyWireASLINK system, and recover
- Power supply for the
the connection.
AnyWireASLINK
- Con rm the power status of the
system itself is not
AnyWireASLINK system, and turn on
turned on.
the power.
- Directly connected to
- Re-connect to the AnyWireASLINK
24-0V power supply.
system.
- The ASLINKSENSOR
- Set any address number other than
maintains the
255.
address number 255
(default setting).
- The ASLINKSENSOR
- Look for the other unit which has the
has an address
same error indication, and set any
redundant with
address number different from it.
another unit.
- Transmission signal
- Decrease the number of units
level reduction has
connected to the same
been detected.
AnyWireASLINK system.
- Shorten the transmission line
between the ASLINKSENSOR and
the master unit.
- The sensing level
- Con rm the ASLINKSENSOR status,
has been reduced.
adjust the position, and clean the
detection surface.
- Teaching is not
- Make sure to perform teaching
normally operated.
operation again.
Measures
Check the parameter and set the correct
parameter.
Measures
Details
[Speci cations]
■General Speci cations
Ambient temperature/humidity for use
Ambient temperature/humidity for storage
Atmosphere for use
Altitude of use *
Pollution level *
*1 Do not use or store the AnyWireASLINK device in an environment pressurized equal to
or higher than the atmospheric pressure at an altitude of 0m. Doing so could cause a
malfunction.
*2 Index that indicates the occurrence of conductive material in the environment where
the device is used.
Contamination level 2 indicates that only non-conductive contamination occurs.
However, incidental condensation could create temporary conductivity in this
environment.
■Transmission speci cations
Power supply voltage
for use
Transmission method
Synchronization method
Transmission procedure
Connection mode
Number of connection points
Number of units connected
RAS feature
■Individual speci cations
Number of occupied points
Consumption current
Detection method
Shield presence/absence
Detection target *
Standard detection objects
Detection distance
(At ambient temperature
of 23°C)
Stable detection
distance
Hysteresis
Response time *
Default
Impact from
variable
temperature
M12 : 18
M18 : 24
M30 : 26
Impact from voltage
5
80
Protective structure
M12 : 19
Mass
M18 : 25
(This product/Cable)
M30 : 27
Mass
50
(Nuts/Washer)
0
*3 The detection distance depends on the material.
*4 Time from when ON or OFF is detected until the transmission signal is transmitted.
0
The time combining this time and the transmission 2 cycle time is the transmission
delay time.
0
0
-BSK4117M**1K 8/9-
-10 - 60°C, 10 - 90%RH (No condensation)
-25 - 75°C, 10 - 90%RH (No condensation)
No corrosive gas
0 to 2000m
1
2 or less
2
Voltage 24V DC +15% to -10% (21.6 to 27.6V DC
Ripple of 0.5Vp-p max.
DC power supply superimposed total frame/cyclic method
Frame/bit synchronization method
Dedicated protocol
Bus type
(Multi-drop method, T-branch method, Tree branch method)
512 max. (IN: 256, OUT: 256)
Up to 128 units
Transmission line disconnection detection,
transmission line short-circuit detection,
transmission power supply reduction detection,
ID redundancy, ID not set detection
One-point input
Supplied via AnyWireASLINK transmission signal (DP, DN)
M12: 13mA
M18: 13mA
Electromagnetic induction detection
Shield type
Non-magnetic metal/Magnetic metal
3
M12: Aluminum 12×12×3mm M30: Aluminum 30×30×3mm
M18: Aluminum 18×18×3mm
M12: 2mm (max.)
M18: 5mm (max.)
M12: 0 to 1.6mm
M18: 0 to 4.5mm
Depends on parameter setting
Max. 10ms
4
Detection distance at 23°C
M12: Within ±20%
M18: Within ±10%
Within ±1% of the detection distance with the
AnyWireASLINK master supplied power voltage
within range of 27.6 to 21.6V
IP67
M12: Approx. 37g
M18: Approx. 49g
M12: Approx. 8g
M18: Approx. 19g
M30: 13mA
M30: 10mm (max.)
M30: 0 to 9.0mm
M30: Within ±10%
M30: Approx. 105g
M30: Approx. 41g