Anywire ASLINKSENSOR BS-K4117-M 1K Series Manual do produto - Página 8

Procurar online ou descarregar pdf Manual do produto para Acessórios Anywire ASLINKSENSOR BS-K4117-M 1K Series. Anywire ASLINKSENSOR BS-K4117-M 1K Series 9 páginas.

[Troubleshooting]
If the followings are displayed on the LEDs of this product, take
measures as shown below.
LINK
IN
ALM
Off
Off
Off
On
Off
Off
Flashing
Flashing
Off
(0.5 seconds
(0.5 seconds
alternately)
alternately)
Flashing
(On for
0.2 seconds,
off for
1.0 seconds)
Flashing
On
Flashing
Flashing
(0.1 seconds
alternately)
When the following error is indicated on the address writer, take
measures as shown below.
Indication
Cause
[E-0303]
The set parameter is incorrect.
Take measures as follows in the following case.
Symptom
Detection cannot be
- Is the detected metal in the appropriate location?
performed.
→ Make adjustments so that the detected metal is within an appropriate range
from the ASLINKSENSOR detection surface.
- Is wiring correct?
→ Con rm that the ASLINKSENSOR transmission line is correctly connected
to the AnyWireASLINK transmission line (DP, DN).
- Are the AnyWireASLINK master unit and slave unit powered by a power supply
with the appropriate capacity?
→ Con rm the power supply.
- Did you perform teaching?
→ Perform teaching settings with the work that is actually detected.
- Are you using within the rated detection range?
→ Use within the rated range.
Setting cannot be
- Is wiring correct?
performed with
→ Recon rm the ASLINKSENSOR transmission line connection.
the address writer.
- Is power fed to the AnyWireASLINK system?
→ Con rm the power supply.
- Is the set parameter correct?
→ Check the parameter and set the correct parameter.
[Parameters and items]
Parameter
Variable
[01.]
Threshold
Set the threshold of the sensing level
0 - 100%
to judge presence/absence of detection.
[02.]
0 - 100%
Set change amount of sensing level
Hysteresis
required to turn detection state ON to OFF.
[03.]
Set an upper limit for the alarm
0 - 100%
Alarm value Hi
judgment value.
[04.]
Set a lower limit for the alarm
Alarm value Lo
0 - 100%
judgment value.
[05.]
Set a monitor time for the alarm
Alarm value
3-255
judgment value. (1 = 100ms)
monitor time
[06.]
0
Normally open
Normally open/
1
Normally close
Normally close
[07.]
0
Simple mode
Operation
1
Normal mode
mode
[10.]
0
Delay timer disabled
Delay timer
1
ON/OFF
ON delay timer
2
OFF delay timer
3
ON/OFF delay timer
[11.]
Delay timer
0 - 255
Set the delay time. (1 = 10ms)
value
Cause
Measures
- ASLINKSENSOR is
- Con rm that there is no
not connected to an
disconnection between the
AnyWireASLINK
ASLINKSENSOR and the
system.
AnyWireASLINK system, and recover
- Power supply for the
the connection.
AnyWireASLINK
- Con rm the power status of the
system itself is not
AnyWireASLINK system, and turn on
turned on.
the power.
- Directly connected to
- Re-connect to the AnyWireASLINK
24-0V power supply.
system.
- The ASLINKSENSOR
- Set any address number other than
maintains the
255.
address number 255
(default setting).
- The ASLINKSENSOR
- Look for the other unit which has the
has an address
same error indication, and set any
redundant with
address number different from it.
another unit.
- Transmission signal
- Decrease the number of units
level reduction has
connected to the same
been detected.
AnyWireASLINK system.
- Shorten the transmission line
between the ASLINKSENSOR and
the master unit.
- The sensing level
- Con rm the ASLINKSENSOR status,
has been reduced.
adjust the position, and clean the
detection surface.
- Teaching is not
- Make sure to perform teaching
normally operated.
operation again.
Measures
Check the parameter and set the correct
parameter.
Measures
Details
[Speci cations]
■General Speci cations
Ambient temperature/humidity for use
Ambient temperature/humidity for storage
Atmosphere for use
Altitude of use *
Pollution level *
*1 Do not use or store the AnyWireASLINK device in an environment pressurized equal to
or higher than the atmospheric pressure at an altitude of 0m. Doing so could cause a
malfunction.
*2 Index that indicates the occurrence of conductive material in the environment where
the device is used.
Contamination level 2 indicates that only non-conductive contamination occurs.
However, incidental condensation could create temporary conductivity in this
environment.
■Transmission speci cations
Power supply voltage
for use
Transmission method
Synchronization method
Transmission procedure
Connection mode
Number of connection points
Number of units connected
RAS feature
■Individual speci cations
Number of occupied points
Consumption current
Detection method
Shield presence/absence
Detection target *
Standard detection objects
Detection distance
(At ambient temperature
of 23°C)
Stable detection
distance
Hysteresis
Response time *
Default
Impact from
variable
temperature
M12 : 18
M18 : 24
M30 : 26
Impact from voltage
5
80
Protective structure
M12 : 19
Mass
M18 : 25
(This product/Cable)
M30 : 27
Mass
50
(Nuts/Washer)
0
*3 The detection distance depends on the material.
*4 Time from when ON or OFF is detected until the transmission signal is transmitted.
0
The time combining this time and the transmission 2 cycle time is the transmission
delay time.
0
0
-BSK4117M**1K 8/9-
-10 - 60°C, 10 - 90%RH (No condensation)
-25 - 75°C, 10 - 90%RH (No condensation)
No corrosive gas
0 to 2000m
1
2 or less
2
Voltage 24V DC +15% to -10% (21.6 to 27.6V DC
Ripple of 0.5Vp-p max.
DC power supply superimposed total frame/cyclic method
Frame/bit synchronization method
Dedicated protocol
Bus type
(Multi-drop method, T-branch method, Tree branch method)
512 max. (IN: 256, OUT: 256)
Up to 128 units
Transmission line disconnection detection,
transmission line short-circuit detection,
transmission power supply reduction detection,
ID redundancy, ID not set detection
One-point input
Supplied via AnyWireASLINK transmission signal (DP, DN)
M12: 13mA
M18: 13mA
Electromagnetic induction detection
Shield type
Non-magnetic metal/Magnetic metal
3
M12: Aluminum 12×12×3mm M30: Aluminum 30×30×3mm
M18: Aluminum 18×18×3mm
M12: 2mm (max.)
M18: 5mm (max.)
M12: 0 to 1.6mm
M18: 0 to 4.5mm
Depends on parameter setting
Max. 10ms
4
Detection distance at 23°C
M12: Within ±20%
M18: Within ±10%
Within ±1% of the detection distance with the
AnyWireASLINK master supplied power voltage
within range of 27.6 to 21.6V
IP67
M12: Approx. 37g
M18: Approx. 49g
M12: Approx. 8g
M18: Approx. 19g
M30: 13mA
M30: 10mm (max.)
M30: 0 to 9.0mm
M30: Within ±10%
M30: Approx. 105g
M30: Approx. 41g