Duerkopp Adler 506 설치 지침 매뉴얼 - 페이지 7

{카테고리_이름} Duerkopp Adler 506에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Duerkopp Adler 506 8 페이지.
Duerkopp Adler 506에 대해서도 마찬가지입니다: 사용 설명서 (17 페이지)

Duerkopp Adler 506 설치 지침 매뉴얼

3.5 Checking the Positioning

8
Before commissioning check the positioning set at the factory.
1
After being turned on the unit must position in the 2nd needle position
(thread lever high position).
Checking the positioning
Turn the main switch off.
By turning the handwheel bring the thread lever into a middle
position.
Turn the main switch on.
The unit positions in the 2nd needle position
(thread lever high position).
Check the position of the thread lever.
Correct the positioning if necessary.
Correcting the positioning
Loosen the clamping screws 2 on the synchronizer ring 1.
Hold the synchronizer ring 1 tight.
By turning the handwheel bring the thread lever into its upper dead
center.
Tighten the clamping screws 2.
Check the positioning again.
For setting the 1st and 3rd needle positions see the Service
Instructions.
2