Duerkopp Adler 506 Handleiding voor installatie-instructies

3.5 Checking the Positioning

8
Before commissioning check the positioning set at the factory.
1
After being turned on the unit must position in the 2nd needle position
(thread lever high position).
Checking the positioning
Turn the main switch off.
By turning the handwheel bring the thread lever into a middle
position.
Turn the main switch on.
The unit positions in the 2nd needle position
(thread lever high position).
Check the position of the thread lever.
Correct the positioning if necessary.
Correcting the positioning
Loosen the clamping screws 2 on the synchronizer ring 1.
Hold the synchronizer ring 1 tight.
By turning the handwheel bring the thread lever into its upper dead
center.
Tighten the clamping screws 2.
Check the positioning again.
For setting the 1st and 3rd needle positions see the Service
Instructions.