INSTALLATION
Truck Requirements
Truck Relief Setting
152 bar Recommended
241 bar Maximum
Truck Flow Volume
80R/100R-IFS
80R/100R-ISS
➀ Cascade R-Series Integral Attachments are compatible with
SAE 10W petroleum base hydraulic fluid meeting Mil. Spec.
MIL-0-5606 or MIL-0-2104B. Use of synthetic or aqueous base
hydraulic fluid is not recommended. If fire resistant hydraulic
fluid is required, special seals must be used. Contact Cascade.
➁ Flow less than recommended will result in slow fork positioning
and sideshift speed.
➂ Flow greater than maximum can result in excessive heating,
reduced system performance and short hydraulic system life.
Auxiliary Valve Functions
Check for compliance with ANSI (ISO) standards:
Hydraulic Supply
IN0019.eps
6
➀
Min.
➁
Recommended Max.
4 L/min.
7.5 L/min.
➂
12 L/min.
IN0018.eps
Tilt Forward
Hoist Down
GA0082.eps
Hoist Up
Tilt Back
Fork Positioning and Sideshift function: No. 8 hose/
No. 8 fittings with 10 mm minimum ID.
Refer to Cascade Hose & Cable Reel Selection Guide,
B
Part No. 212199 to select the correct hose reel for the
mast and truck.
C
Sideshifting
A
Mast Single Internal Reeving
OR
A
B
Hose Reel
Fork Positioning & Sideshifting
A
Mast Double Internal Reeving
OR
C
Mast Single Internal Reeving and Hose Reel
Sideshift
Left
Open Forks (if equipped)
Close Forks (if equipped)
Sideshift
Right