Symptom
Possible Faults
Controller does
Internal fuse failure.
not function
(no lights).
Controller or associated
wiring has tripped the
mains circuit breaker or
RCD.
Pump does not
Pump failure.
run, top-up and
other functions
Controller Damaged.
seem ok.
For all other
Contact your system
faults.
supplier.
TCA5000950 v1.3
Solution
Have the controller's internal fuses checked by a
qualified electrician and replaced if necessary. If the
unit fails again, contact your supplier for replacement.
If in any doubt please consult a qualified electrician or
electronic technician.
Have the supply circuit checked by a qualified
electrician. Check circuit breaker is of a suitable rating
(10A Type B recommended), also test wiring
insulation and earth. If the supply circuit is proved to
have no fault, contact your supplier for replacement.
Unplug the pump and test separately.
The control unit can supply up to 10A at 240v to the
pump. It may be damaged if this specification is
exceeded.
If your system supplier is no longer trading, you may
consult 3P Technik UK.