Airvolution Esatto ESL60D2S 사용자 설명서 - 페이지 10
{카테고리_이름} Airvolution Esatto ESL60D2S에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Airvolution Esatto ESL60D2S 19 페이지. Slide-out rangehood 60 cm
Installation height:
For optimum performance, it is recommended that the rangehood be installed at a height of
between 650-750mm from the cooking surface. See Fig. for detailed AS/NZS minimum distance
requirements.
Rear-mounting to the wall
• Using a spirit level, mark a horizontal line on the wall where the rangehood base will be, observing
all necessary clearances (Fig. ). Check the required clearances in your cooktop/stove manual and,
should they be greater than those specifi ed in Fig. , make sure to observe them.
Fig.
Minimum distance
– Electric:
– Gas:
Maximum distance
– Either:
Top of
cooktop
• Drill 4 holes of Ø8mm on the wall, as illustrated below (Fig. ).
• Hammer the wall plugs into the holes, then insert two ST4x30mm screws into the lower wall plugs.
Tighten the screws, but leave a 2mm gap so that you can hang the rangehood on the screws in the
keyhole slots.
• Hang the hood to the wall screws, and make sure the hood is in balance and positioned correctly.
• Take away the Aluminum Filters, mark and drill another 2 holes of Ø8mm on the wall . (Safety Screw
Holes)
• Take back the hood and hammer the wall plugs, hang the hood again and fi x the hood with two
ST4x30mm screws.
WARNING: Failure to install the screws or fi xing device in accordance with these instructions may
result in electrical hazards!
600mm
650mm
750mm
Rangehood base
Fig.