Danfoss 176F3167 애플리케이션 매뉴얼 - 페이지 4

{카테고리_이름} Danfoss 176F3167에 대한 애플리케이션 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Danfoss 176F3167 8 페이지. Top fan kit for fa09-fa12/d3h-d4h/e3h-e4h

Danfoss 176F3167 애플리케이션 매뉴얼
Top Fan Kit for FA09-FA12/D3h-D4h/E3h-E4h
Application Guide
5.
Lift the grill and top fan from the frequency converter.
1
2
3
4
5
6
Illustration 1: Top Fan with Grill
1
Screw (T25)
2
Top fan grill
3
Top fan
2.4 Installing the Top Fan and Grill
To install the top fan and grill, use the following steps.
1.
Feed the top fan cable through the cable access hole on the top of the frequency converter.
2.
Reconnect the in-line fan cable connector.
3.
Position the fan on top of the frequency converter with the air direction arrows pointing upward and away from the unit.
4.
Place the grill on top of the fan.
5.
Fasten 2 screws (T25) in opposite corners of the grill, securing the top fan to the frequency converter.
6.
Position the front cover on the frequency converter, and fasten with 2 screws (T25).
4 | Danfoss A/S © 2022.03
4
Top fan cable and connector
5
Top vent
6
Cable access hole
AN389655468601en-000101 / 130R0767
Installation