Aolait AL350RX 사용자 설명서 - 페이지 16
{카테고리_이름} Aolait AL350RX에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Aolait AL350RX 17 페이지.
Gobo replacement
Identification of gobo wheel
To replace a gobo:
• Disconnect the fixture from power and allow to cool.
• Position the head and apply the tilt lock.
• Remove the rear head cover located on the same side as the pan lock
(A). See figure below.
• Remove the gobo wheel cover for access to the gobo wheel.
• Turn the gobo wheel until the gobo you want to replace is accessible.
• Unhook the end of the spring and turn it upwards. Pull the gobo holder
out of the gobo wheel.
Service and maintenance
Warning! Read "Safety Information" on page 5 before servicing this light
Warning! Disconnect the fixture from AC mains power and allow to cool for at least 10 minutes before
handling. Do not view the light output from less than 4 meters
prepared for the fixture to light suddenly if connected to power.
Warning! Refer any service operation not described in this user manual to a qualified service
technician.
Important! Excessive dust, smoke fluid, and particle buildup degrades performance, causes overheating and
will damage the fixture. Damage caused by inadequate cleaning or maintenance is
not covered by the product warranty.
Following are a few common problems that may occur during operation. Here are some suggestions
for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connect power and main fuse.
2. Measure the mains voltage on the main connector.
3. Check the power on LED to see if it can be light up or not.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX connectors, cables to see if they are linked properly.
2. If the DMX LED is on and no response to the channel, check the address settings and DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the unit or the
previous one.
4. Try to use another DMX controller.
5. Check to see if the DMX cables run near or run alongside to high voltage cables that may cause damage
or interference to DMX interface circuit.
C. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
2. The motor's drive IC on the PCB might be out of condition.
D. The lamp is cutting out intermittently
1. The lamp is not working well. Check the mains voltage either too high or too low.
2. Internal temperature may be too high. Check if replacement of fan is needed on the head.
without shade 4-5 welding goggles. Be
19
.