Synchro Mode in case of a double bed
This motors can also be connected to remote controls TOPLINE in a 'synchro' way;
in the Synchro Mode both bed parts will be adjusted at the same time by one single
remote. This by using the optional Synchro Cable.
Connect the synchro cable (X-cable - male socket) to both motors. This in the
7-pole socket, next to the connecting button A.
The synchro function is activated by default after connecting the Synchro
Cable.
Programming MEMORY positions
You can store 2 positions of the bed in the memory using the M1 and M2
keys.
Put the bed in a position you want to store.
Press programming key D until the buttons M1 and M2 light up (after 3 sec.).
Now press M1 or M2 to store the current position.
The white LED on the motor flashes 2 x and will go out. The position was
stored.
PROBLEM CASE: Reset of the receiver (factory settings)
If problems occur during the installation of the motor and the remote controls you
may reset the receiver and repeat the connecting procedure:
HOW TO RESET THE RECEIVER:
Press 4 x the connecting button A of the motor until the LED light goes on,
afterwards please press a 5th time.
The white LED flashes 2 x and will go out. The receiver went back to the
original factory settings.
The connecting procedure between remote and receiver can now be
executed as described above.
moving to their Zero Position. When the white LED light on the
motor flashes 2 x, the reference movement was successful.
The adjustable bed is now ready to be used.