4.
Disassembling and
assembling of the
swash plate
10
Disassembling and assembling PAHT and PAHT G 256-308
WARNING:
Make sure that the surface on the swash
plate does not get any marks.
1. Place the swash plate upside down.
Remove the 2 bolts holding the swash
plate. Remove the mounting flange from
the swash plate.
3. Change the O-ring on the mounting
flange.
180R9268 / 521B1236 / DKCFN.PI.011.B3.02 / 01.2015
2. Check that the O-ring and pin are in good
condition (Provided with sealing set).
4. Mount the swash plate on the 2 pins.
Carefully by hand tilt the unit to
horizontal position and mount the 2 bolts
which hold the swash plate. Tighten the
bolts with a torque of 30 Nm +/-2 Nm.
Finally check the surface on the swash
plate for any marks or foreign particles.
Mount the assembled part on the pump.