2

TECHNICAL SPECIFICATIONS

Detectable spectrum
Temperature of the object to be
detected
Distance of detection (fig. 7)
Range of the observation field (fig. 8)
Digital inputs
Digital outputs
Response time
ON
OFF
Power supply
Power supply of cooling device
Working temperature
Storage temperature
Degree of protection
Dimensions (not including connectors)
Weight
Certified by OneDoc A.620.107 Rev.04-MU 26/145 #1061394
Danieli Automation Standard - Installation Use and Maintenance Manual - ID2202
850 .. 1700 nm
≥ 450° C (842° F) HIGH sensitivity
≥ 650° C (1202° F) LOW sensitivity
500 .. 2,000 mm
vertical: 12°
horizontal: 3°
24 Vdc / 5 mA
PNP, Imax = 200 mA, output connections protected
against short circuits.
typ. 0.2 ms (min 0.1, max 0.3 ms)
typ. 0.3 ms (min 0.2, max 0.5 ms)
rated voltage 24 Vdc (20 .. 32Vdc) @ 50mA
water, filtered < 300 µm, 3-5 L/min @ 0.2 bar, 2 bar max
1/4" GAS threads
-40 .. +70 ° C (-40 .. 158 ° F)
-40 .. +70 ° C (-40 .. 158 ° F)
IP66 (NEMA 4X)
266 x 180 x 64 mm (10.5" x 7.1" x 2.5")
1.7 kg (3.7 lb)