Contech VortSentry HS36 유지 관리 매뉴얼 - 페이지 3

{카테고리_이름} Contech VortSentry HS36에 대한 유지 관리 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Contech VortSentry HS36 3 페이지. Stormwater treatment system

VortSentry HS Model:
Water depth
Date
to shipment
1
1.
The water depth to sediment is determined by taking two measurements with a stadia rod: one measurement from the manhole opening to the
top of the sediment pile and the other from the manhole opening to the water surface. If the difference between these measurements is less
than the distance given in Table 1, the system should be cleaned out. Note: To avoid underestimating the volume of sediment in the chamber, the
measuring device must be carefully lowered to the top of the sediment pile.
2.
For optimum performance, the system should be cleaned out when the floating hydrocarbon layer accumulates to an appreciable thickness. In
the event of an oil spill, the system should be cleaned immediately.
VortSentry HS Inspection & Maintenance Log
Describe
Floatable layer
maintenance
thickness
2
performed
Location:
Maintenance
Personnel
Comments