Apogee Symphony I/O Mk II SoundGrid 사용자 설명서 - 페이지 12

{카테고리_이름} Apogee Symphony I/O Mk II SoundGrid에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Apogee Symphony I/O Mk II SoundGrid 20 페이지. For units equipped with the wsg option card

Apogee Symphony I/O Mk II SoundGrid 사용자 설명서

Clock Screen

Use the Clock page to set the clock source and sample rate for the device and to assess clock status. Clock
controls are on the left side of the page, status indicators are on the right.
● Source​ - Sets the clock source.
○ Internal​ - The Symphony I/O Mk II's internal clock is used
○ External WC​ - Clock is provided by an external device via the Symphony I/O Mk II's Word Clock
Input connector
○ Digital​ - Clock is provided by an external device via the Symphony I/O Mk II's digital audio input
connector. When this option is selected, additional settings appear:
─ SPDIF Coax​ - Clock is provided to the selected SPDIF Coax input
─ ADAT​ - Clock is provided to the selected ADAT optical input
─ AES​ - Clock is provided to the selected AES input
● Sample Rate​ - Sets the sample rate when Clock Source is set to Internal.
○ Sample Rate can be set to 44.1 / 48 / 88.2 / 96 kHz.
─ If Source is set to anything other than Internal, the Sample Rate menu is grayed out and
inoperative.
─ A SoundGrid system's maximum sample rate is 96kHz
● Input Word Clock Termination​ - Terminates the BNC Word Clock Input connector on the rear panel of
Symphony I/O Mk II. In general, leave this Input Termination on at all times. This applies even when
Symphony I/O Mk II is being used as the master clock for other devices. The only time this should be
turned off is when Symphony I/O Mk II is slaving to external clock AND passing the signal through the
BNC Out to another device.
APOGEE SYMPHONY I/O MK II SOUNDGRID USER'S GUIDE
Page 12